New release of MULTIPSK 4.45.6.1 + updated list of the RS ID#Multipsk #RS ID #rs


Patrick Lindecker
 

Hello to all,

 

The new release of MultiPSK (4.45.6.1) is on my Web site (http://f6cte.free.fr/index_anglais.htm).
The mirror site is Earl's, W8BR: https://www.paazig.net/f6cte/MULTIPSK_setup.exe

A bug on this function, which prevented the transmission of the CQ information to the Multipsk.fr server, has been fixed in 4.45.6.1 version.

 

 

Below it will found the updated list of RS ID, with the new “EM” RS ID (279).

 

UPDATED LIST OF RS ID

 

IF NUMBER=1 THEN MODE:='BPSK31' ELSE

IF NUMBER=2 THEN MODE:='BPSK63' ELSE

IF NUMBER=3 THEN MODE:='QPSK63' ELSE

IF NUMBER=4 THEN MODE:='BPSK125' ELSE

IF NUMBER=5 THEN MODE:='QPSK125' ELSE

IF NUMBER=7 THEN MODE:='PSKFEC31' ELSE

IF NUMBER=8 THEN MODE:='PSK10' ELSE

 

{"MT63" parameter 1 parameter 2 (parameter 1: "500", "1000" (1000 Hz) or "2000" (2000 Hz),

  parameter 2: "LG" (Long), "ST" (Short) or "VST" (Very short)

Example: MT63-1000-LG}

IF NUMBER=9 THEN MODE:='MT63-500-LG' ELSE

IF NUMBER=10 THEN MODE:='MT63-500-ST' ELSE

IF NUMBER=11 THEN MODE:='MT63-500-VST' ELSE

IF NUMBER=12 THEN MODE:='MT63-1000-LG' ELSE

IF NUMBER=13 THEN MODE:='MT63-1000-ST' ELSE

IF NUMBER=14 THEN MODE:='MT63-1000-VST' ELSE

IF NUMBER=15 THEN MODE:='MT63-2000-LG' ELSE

IF NUMBER=17 THEN MODE:='MT63-2000-ST' ELSE

IF NUMBER=18 THEN MODE:='MT63-2000-VST' ELSE

 

IF NUMBER=19 THEN MODE:='PSKAM10' ELSE

IF NUMBER=20 THEN MODE:='PSKAM31' ELSE

IF NUMBER=21 THEN MODE:='PSKAM50' ELSE

IF NUMBER=22 THEN MODE:='PSK63F' ELSE

IF NUMBER=23 THEN MODE:='PSK220F' ELSE

 

{"CHIP 64" parameter 1 (parameter 1: "64" or "128"), Example: CHIP-64}

IF NUMBER=24 THEN MODE:='CHIP-64' ELSE

IF NUMBER=25 THEN MODE:='CHIP-128' ELSE

 

IF NUMBER=26 THEN MODE:='CW' ELSE

 

{"CCW" parameter 1 parameter 2 (parameter 1: "OOK" or "FSK",

   parameter 2: "12" (12 wpm), "24" (24 wpm) or "48" (48 wpm)

  Examples: CCW-OOK-12 or CCW-FSK-24}

IF NUMBER=27 THEN MODE:='CCW-OOK-12' ELSE

IF NUMBER=28 THEN MODE:='CCW-OOK-24' ELSE

IF NUMBER=29 THEN MODE:='CCW-OOK-48' ELSE

IF NUMBER=30 THEN MODE:='CCW-FSK-12' ELSE

IF NUMBER=31 THEN MODE:='CCW-FSK-24' ELSE

IF NUMBER=33 THEN MODE:='CCW-FSK-48' ELSE

 

{Pactor1 ARQ not RX/TX in Multipsk 4.1.1}

IF NUMBER=34 THEN MODE:='PACTOR1-FEC' ELSE

 

{"PACKET" parameter 1 (parameter 1: "300" (bauds) or "1200" (bauds)),Example: PACKET-300}

IF NUMBER=35 THEN MODE:='PACKET-300' ELSE

IF NUMBER=36 THEN MODE:='PACKET-1200' ELSE

 

{"ASCII" parameter 1 (parameter 1: "7" (7 bits) or "8" (8 bits)), Example: ASCII-7}

IF NUMBER=37 THEN MODE:='ASCII-7' ELSE

IF NUMBER=38 THEN MODE:='ASCII-8' ELSE

 

{"RTTY" parameter 1 (parameter 1: "45" (45 bauds), "50" (50 bauds), "75" (75 bauds)), Example: RTTY-45}

IF NUMBER=39 THEN MODE:='RTTY-45' ELSE

IF NUMBER=40 THEN MODE:='RTTY-50' ELSE

IF NUMBER=41 THEN MODE:='RTTY-75' ELSE

 

IF NUMBER=42 THEN MODE:='AMTOR FEC' ELSE

 

{"THROB" parameter 1 (parameter 1: "1" (1 baud), "2" (2 bauds) or "4" (4 bauds)), Example: THROB-2}

IF NUMBER=43 THEN MODE:='THROB-1' ELSE

IF NUMBER=44 THEN MODE:='THROB-2' ELSE

IF NUMBER=45 THEN MODE:='THROB-4' ELSE

 

{"THROBX" parameter 1 (parameter 1: "1" (1 baud) or "2" (2 bauds)), Example: THROBX-2}

IF NUMBER=46 THEN MODE:='THROBX-1' ELSE

IF NUMBER=47 THEN MODE:='THROBX-2' ELSE

 

{"CONTESTIA" parameter 1 parameter 2 (parameter 1: "4" (4 tones),  "8" (8 tones), "16" (16 tones), "32" (32 tones), parameter 2: "250" (B=250 Hz), "500" (B=500 Hz) or "1000" (B=1000 Hz))...same parameters as OLIVIA

  Examples: CONTESTIA-32-1000 or CONTESTIA-8-500

  Note: the following are the main Contestia modes:

  CONTESTIA-4-250, CONTESTIA-4-500, CONTESTIA-8-250, CONTESTIA-8-500, CONTESTIA-16-500, CONTESTIA-16-1000, CONTESTIA-32-1000}

IF NUMBER=49 THEN MODE:='CONTESTIA-8-250' ELSE

IF NUMBER=50 THEN MODE:='CONTESTIA-16-500' ELSE

IF NUMBER=51 THEN MODE:='CONTESTIA-32-1000' ELSE

IF NUMBER=52 THEN MODE:='CONTESTIA-8-500' ELSE

IF NUMBER=53 THEN MODE:='CONTESTIA-16-1000' ELSE

IF NUMBER=54 THEN MODE:='CONTESTIA-4-500' ELSE

IF NUMBER=55 THEN MODE:='CONTESTIA-4-250' ELSE

 

IF NUMBER=56 THEN MODE:='VOICE' ELSE

IF NUMBER=57 THEN MODE:='MFSK16' ELSE

IF NUMBER=60 THEN MODE:='MFSK8' ELSE

 

{"RTTYM" parameter 1 parameter 2 (parameter 1: "4" (4 tones),  "8" (8 tones), "16" (16 tones), "32" (32 tones), parameter 2: "250" (B=250 Hz), "500" (B=500 Hz) or "1000" (B=1000 Hz))...same parameters as OLIVIA

Examples: RTTYM-32-1000 or RTTYM-8-500

Note: the following are the main RTTYM modes: RTTYM-4-250, RTTYM-4-500, RTTYM-8-250, RTTYM-8-500, RTTYM-16-500, RTTYM-16-1000, RTTYM-32-1000}

IF NUMBER=61 THEN MODE:='RTTYM-8-250' ELSE

IF NUMBER=62 THEN MODE:='RTTYM-16-500' ELSE

IF NUMBER=63 THEN MODE:='RTTYM-32-1000' ELSE

IF NUMBER=65 THEN MODE:='RTTYM-8-500' ELSE

IF NUMBER=66 THEN MODE:='RTTYM-16-1000' ELSE

IF NUMBER=67 THEN MODE:='RTTYM-4-500' ELSE

IF NUMBER=68 THEN MODE:='RTTYM-4-250' ELSE

 

{"OLIVIA" parameter 1 parameter 2 (parameter 1: "4" (4 tones),  "8" (8 tones), "16" (16 tones), "32" (32 tones), parameter 2: "250" (B=250 Hz), "500" (B=500 Hz) or "1000" (B=1000 Hz))

Examples: OLIVIA-32-1000 or OLIVIA-8-500

Note: the following are the main Olivia modes: OLIVIA-4-250, OLIVIA-4-500, OLIVIA-8-250, OLIVIA-8-500, OLIVIA-16-500, OLIVIA-16-1000, OLIVIA-32-1000}

IF NUMBER=69 THEN MODE:='OLIVIA-8-250' ELSE

IF NUMBER=70 THEN MODE:='OLIVIA-16-500' ELSE

IF NUMBER=71 THEN MODE:='OLIVIA-32-1000' ELSE

IF NUMBER=72 THEN MODE:='OLIVIA-8-500' ELSE

IF NUMBER=73 THEN MODE:='OLIVIA-16-1000' ELSE

IF NUMBER=74 THEN MODE:='OLIVIA-4-500' ELSE

IF NUMBER=75 THEN MODE:='OLIVIA-4-250' ELSE

 

IF NUMBER=76 THEN MODE:='PAX' ELSE

IF NUMBER=77 THEN MODE:='PAX2' ELSE

IF NUMBER=78 THEN MODE:='DOMINOF' ELSE

IF NUMBER=79 THEN MODE:='FAX' ELSE

{the sub-modes SSTV are automatically recognized in SSTV so no parameters are needed for SSTV}

IF NUMBER=81 THEN MODE:='SSTV' ELSE

 

{"DOMINOEX" parameter 1 and optionally parameter 2 (parameter 1: "4" (4 baud) , "5" (5 bauds),

  "8" (8 bauds), "11" (11 bauds), "16" (16 bauds), "22" (22 bauds),

  parameter 2 "" (no parameter 2 for non-FEC) or "FEC" (for FEC correction))

Example: DOMINOEX-11 or DOMINOEX-16-FEC (parameter 2 is optional)}

IF NUMBER=84 THEN MODE:='DOMINOEX-4' ELSE

IF NUMBER=85 THEN MODE:='DOMINOEX-5' ELSE

IF NUMBER=86 THEN MODE:='DOMINOEX-8' ELSE

IF NUMBER=87 THEN MODE:='DOMINOEX-11' ELSE

IF NUMBER=88 THEN MODE:='DOMINOEX-16' ELSE

IF NUMBER=90 THEN MODE:='DOMINOEX-22' ELSE

IF NUMBER=92 THEN MODE:='DOMINOEX-4-FEC' ELSE

IF NUMBER=93 THEN MODE:='DOMINOEX-5-FEC' ELSE

IF NUMBER=97 THEN MODE:='DOMINOEX-8-FEC' ELSE

IF NUMBER=98 THEN MODE:='DOMINOEX-11-FEC' ELSE

IF NUMBER=99 THEN MODE:='DOMINOEX-16-FEC' ELSE

IF NUMBER=101 THEN MODE:='DOMINOEX-22-FEC' ELSE

 

IF NUMBER=104 THEN MODE:='FELD HELL' ELSE

IF NUMBER=105 THEN MODE:='PSK HELL' ELSE

IF NUMBER=106 THEN MODE:='HELL 80' ELSE

 

{"FMHELL" parameter 1 (parameter 1: "105" (105 bauds) or "245" (245 bauds)),

Example: FMHELL-245}

IF NUMBER=107 THEN MODE:='FM HELL-105' ELSE

IF NUMBER=108 THEN MODE:='FM HELL-245' ELSE

 

IF NUMBER=110 THEN MODE:='QPSK31' ELSE

 

{"PACKET" parameter 1 (parameter 1: "110" (bauds),Example: PACKET-110}

IF NUMBER=113 THEN MODE:='PACKET-110' ELSE

 

IF NUMBER=114 THEN MODE:='141A' ELSE

 

IF NUMBER=116 THEN MODE:='OLIVIA-8-1000' ELSE

IF NUMBER=117 THEN MODE:='CONTESTIA-8-1000' ELSE

IF NUMBER=119 THEN MODE:='RTTYM-8-1000' ELSE

 

IF NUMBER=123 THEN MODE:='DTMF' ELSE

 

IF NUMBER=125 THEN MODE:='ALE400' ELSE

 

IF NUMBER=126 THEN MODE:='BPSK250' ELSE

IF NUMBER=127 THEN MODE:='QPSK250' ELSE

 

IF NUMBER=131 THEN MODE:='FDMDV' ELSE

 

IF NUMBER=132 THEN MODE:='JT65-A' ELSE

IF NUMBER=134 THEN MODE:='JT65-B' ELSE

IF NUMBER=135 THEN MODE:='JT65-C' ELSE

 

IF NUMBER=136 THEN MODE:='THOR-4' ELSE

IF NUMBER=137 THEN MODE:='THOR-8' ELSE

IF NUMBER=138 THEN MODE:='THOR-16' ELSE

IF NUMBER=139 THEN MODE:='THOR-5' ELSE

IF NUMBER=143 THEN MODE:='THOR-11' ELSE

IF NUMBER=145 THEN MODE:='THOR-22' ELSE

 

IF NUMBER=146 THEN MODE:='THROBX-4' ELSE

 

IF NUMBER=147 THEN MODE:='MFSK32' ELSE

IF NUMBER=148 THEN MODE:='MFSK11' ELSE

IF NUMBER=152 THEN MODE:='MFSK22' ELSE

 

IF NUMBER=153 THEN MODE:='CALL ID' ELSE

 

{"PACKET" parameter 1 (parameter 1: "PSKbauds")}

IF NUMBER=155 THEN MODE:='PACKET-PSK1200' ELSE

IF NUMBER=156 THEN MODE:='PACKET-PSK250' ELSE

IF NUMBER=159 THEN MODE:='PACKET-PSK63' ELSE

 

IF NUMBER=163 THEN MODE:='OLIVIA-8-125' ELSE

IF NUMBER=169 THEN MODE:='CONTESTIA-8-125' ELSE

IF NUMBER=170 THEN MODE:='RTTYM-8-125' ELSE

 

{MIL-STD-188-110A in asynchronous format 8N1 (8 data bits, no parity, 1 stop bit)}

IF NUMBER=172 THEN MODE:='110A-8N1' ELSE

 

IF NUMBER=173 THEN MODE:='BPSK500' ELSE

 

{ "PSK Robust" or "PSKR" in short}

IF NUMBER=183 THEN MODE:='PSK125R' ELSE

IF NUMBER=186 THEN MODE:='PSK250R' ELSE

IF NUMBER=187 THEN MODE:='PSK500R' ELSE

 

{"PACKET" PSK at 31 bauds (parameter 1: "PSKbauds")}

IF NUMBER=189 THEN MODE:='PACKET-PSK31' ELSE

 

{Contestia modes for UHF and emergency communications }

IF NUMBER=191 THEN MODE:='CONTESTIA-64-2000' ELSE

IF NUMBER=193 THEN MODE:='CONTESTIA-64-1000' ELSE

IF NUMBER=194 THEN MODE:='CONTESTIA-64-500' ELSE

IF NUMBER=201 THEN MODE:='CONTESTIA-32-2000' ELSE

 

{additive Olivia and Contestia modes}

IF NUMBER=203 THEN MODE:='OLIVIA-4-125' ELSE

IF NUMBER=204 THEN MODE:='CONTESTIA-4-125' ELSE

IF NUMBER=211 THEN MODE:='OLIVIA-64-2000' ELSE

IF NUMBER=214 THEN MODE:='OLIVIA-8-2000' ELSE

IF NUMBER=221 THEN MODE:='OLIVIA-32-2000' ELSE

IF NUMBER=229 THEN MODE:='OLIVIA-4-1000' ELSE

IF NUMBER=234 THEN MODE:='OLIVIA-16-2000' ELSE

IF NUMBER=238 THEN MODE:='OLIVIA-4-2000' ELSE

IF NUMBER=247 THEN MODE:='CONTESTIA-8-2000' ELSE

IF NUMBER=254 THEN MODE:='CONTESTIA-4-2000' ELSE

IF NUMBER=255 THEN MODE:='CONTESTIA-4-1000' ELSE

IF NUMBER=259 THEN MODE:='CONTESTIA-16-2000' ELSE

IF NUMBER=261 THEN MODE:='CONTESTIA-128-2000' ELSE

 

{mode Lentus}

IF NUMBER=262 THEN MODE:='LENTUS' ELSE

 

{RSID-EOT for “End Of Transmission”, to re-enable a squelch or notify a completion of transfer, for example}

IF NUMBER=263 THEN MODE:='EOT' ELSE //EOT is a pseudo mode here

 

{modes AUTEX}

IF NUMBER=266 THEN MODE:='AUTEX2' ELSE

IF NUMBER=267 THEN MODE:='AUTEX4' ELSE

IF NUMBER=268 THEN MODE:='AUTEX7' ELSE

IF NUMBER=271 THEN MODE:='AUTEX13' ELSE

 

{EM mode (Extended Message) in V.4.45.6}

IF NUMBER=279 THEN MODE:='EM' ELSE

 

{Extension of RSID, for a two sequences RSID code}

IF NUMBER=6 THEN MODE:='EXTENSION_FLDIGI' ELSE

IF NUMBER=102 THEN MODE:='EXTENSION_FLDIGI' ELSE

IF NUMBER=168 THEN MODE:='EXTENSION_FLDIGI' ELSE

IF NUMBER=174 THEN MODE:='EXTENSION_FLDIGI';

 

73

Patrick